NWP_Query Object ( [query] => Array ( [post_type] => kb [post__not_in] => Array ( [0] => 36872 ) [tax_query] => Array ( [0] => Array ( [taxonomy] => kbtopic [field] => slug [terms] => common-issues-chimecom-series ) ) [posts_per_page] => 4 [orderby] => rand ) [query_vars] => Array ( [post_type] => kb [post__not_in] => Array ( [0] => 36872 ) [tax_query] => Array ( [0] => Array ( [taxonomy] => kbtopic [field] => slug [terms] => common-issues-chimecom-series ) ) [posts_per_page] => 4 [orderby] => meta_value_num menu_order [error] => [m] => [p] => 0 [post_parent] => [subpost] => [subpost_id] => [attachment] => [attachment_id] => 0 [name] => [pagename] => [page_id] => 0 [second] => [minute] => [hour] => [day] => 0 [monthnum] => 0 [year] => 0 [w] => 0 [category_name] => [tag] => [cat] => [tag_id] => [author] => [author_name] => [feed] => [tb] => [paged] => 0 [meta_key] => [meta_value] => [preview] => [s] => [sentence] => [title] => [fields] => [menu_order] => [embed] => [category__in] => Array ( ) [category__not_in] => Array ( ) [category__and] => Array ( ) [post__in] => Array ( ) [post_name__in] => Array ( ) [tag__in] => Array ( ) [tag__not_in] => Array ( ) [tag__and] => Array ( ) [tag_slug__in] => Array ( ) [tag_slug__and] => Array ( ) [post_parent__in] => Array ( ) [post_parent__not_in] => Array ( ) [author__in] => Array ( ) [author__not_in] => Array ( ) [search_columns] => Array ( ) [meta_query] => Array ( [relation] => OR [0] => Array ( [key] => mkb_tax_order_5749 [compare] => EXISTS ) [1] => Array ( [key] => mkb_tax_order_5749 [compare] => NOT EXISTS ) ) [order] => ASC [ignore_sticky_posts] => [suppress_filters] => [cache_results] => 1 [update_post_term_cache] => 1 [update_menu_item_cache] => [lazy_load_term_meta] => 1 [update_post_meta_cache] => 1 [nopaging] => [comments_per_page] => 50 [no_found_rows] => [taxonomy] => kbtopic [term] => common-issues-chimecom-series ) [tax_query] => WP_Tax_Query Object ( [queries] => Array ( [0] => Array ( [taxonomy] => kbtopic [terms] => Array ( [0] => common-issues-chimecom-series ) [field] => slug [operator] => IN [include_children] => 1 ) ) [relation] => AND [table_aliases:protected] => Array ( [0] => wp_term_relationships ) [queried_terms] => Array ( [kbtopic] => Array ( [terms] => Array ( [0] => common-issues-chimecom-series ) [field] => slug ) ) [primary_table] => wp_posts [primary_id_column] => ID ) [meta_query] => WP_Meta_Query Object ( [queries] => Array ( [0] => Array ( [key] => mkb_tax_order_5749 [compare] => EXISTS ) [1] => Array ( [key] => mkb_tax_order_5749 [compare] => NOT EXISTS ) [relation] => OR ) [relation] => OR [meta_table] => wp_postmeta [meta_id_column] => post_id [primary_table] => wp_posts [primary_id_column] => ID [table_aliases:protected] => Array ( [0] => wp_postmeta [1] => mt1 ) [clauses:protected] => Array ( [wp_postmeta] => Array ( [key] => mkb_tax_order_5749 [compare] => EXISTS [compare_key] => = [alias] => wp_postmeta [cast] => CHAR ) [mt1] => Array ( [key] => mkb_tax_order_5749 [compare] => NOT EXISTS [compare_key] => = [alias] => mt1 [cast] => CHAR ) ) [has_or_relation:protected] => 1 ) [date_query] => [queried_object] => WP_Term Object ( [term_id] => 5749 [name] => Common Issues [slug] => common-issues-chimecom-series [term_group] => 0 [term_taxonomy_id] => 5749 [taxonomy] => kbtopic [description] => [parent] => 5746 [count] => 2 [filter] => raw [term_order] => 6 ) [queried_object_id] => 5749 [request] => SELECT SQL_CALC_FOUND_ROWS wp_posts.ID FROM wp_posts LEFT JOIN wp_term_relationships ON (wp_posts.ID = wp_term_relationships.object_id) LEFT JOIN wp_postmeta ON ( wp_posts.ID = wp_postmeta.post_id ) LEFT JOIN wp_postmeta AS mt1 ON ( wp_posts.ID = mt1.post_id AND mt1.meta_key = 'mkb_tax_order_5749' ) WHERE 1=1 AND wp_posts.ID NOT IN (36872) AND ( wp_term_relationships.term_taxonomy_id IN (5749) ) AND ( wp_postmeta.meta_key = 'mkb_tax_order_5749' OR mt1.post_id IS NULL ) AND ((wp_posts.post_type = 'kb' AND (wp_posts.post_status = 'publish' OR wp_posts.post_status = 'acf-disabled'))) GROUP BY wp_posts.ID ORDER BY wp_postmeta.meta_value+0 ASC, wp_posts.menu_order ASC LIMIT 0, 4 [posts] => Array ( [0] => WP_Post Object ( [ID] => 36867 [post_author] => 23 [post_date] => 2021-07-26 18:15:21 [post_date_gmt] => 2021-07-27 01:15:21 [post_content] =>

Ensure the SKK-620C is correctly grounded 

  

In a dual-master station system, a loud feedback sound is heard at both master stations. 

This can be caused by a common power supply and/or missing DAK-2S. If both C-ML/A master stations share the same power supply, a ground loop feedback will occur when the talk button is pushed. Install separate SKK-620C power supplies or install batteries for each master station. The DAK-2S "Dual Master Component Modules" must also be installed per the wiring diagram below:          

Communication timeout issues 

If the resistance of the wire is too large, usually from exceeding distance limitations, the master station may not time out as designed. 22AWG = 245'  18AWG = 490'    

Communication volume is too loud or too soft 

It's possible the volume control is not adjusted properly. Remove the front cover of the C-ML/A and locate the volume potentiometer through a hole located at the bottom of the station. Use a small screwdriver to adjust the volume; clockwise to increase, and counterclockwise to decrease. Do not turn the potentiometer too hard in either direction or damage may occur.    [post_title] => Common Communication Troubleshooting for the C-123 Kit [post_excerpt] => [post_status] => publish [comment_status] => open [ping_status] => open [post_password] => [post_name] => common-communication-troubleshooting-for-the-c-123-kit [to_ping] => [pinged] => [post_modified] => 2025-03-12 08:41:18 [post_modified_gmt] => 2025-03-12 15:41:18 [post_content_filtered] => [post_parent] => 0 [guid] => https://aiphone.local/kb/common-communication-troubleshooting-for-the-c-123-kit/ [menu_order] => 0 [post_type] => kb [post_mime_type] => [comment_count] => 0 [filter] => raw ) ) [post_count] => 1 [current_post] => -1 [before_loop] => 1 [in_the_loop] => [post] => WP_Post Object ( [ID] => 36867 [post_author] => 23 [post_date] => 2021-07-26 18:15:21 [post_date_gmt] => 2021-07-27 01:15:21 [post_content] =>

Ensure the SKK-620C is correctly grounded 

  

In a dual-master station system, a loud feedback sound is heard at both master stations. 

This can be caused by a common power supply and/or missing DAK-2S. If both C-ML/A master stations share the same power supply, a ground loop feedback will occur when the talk button is pushed. Install separate SKK-620C power supplies or install batteries for each master station. The DAK-2S "Dual Master Component Modules" must also be installed per the wiring diagram below:          

Communication timeout issues 

If the resistance of the wire is too large, usually from exceeding distance limitations, the master station may not time out as designed. 22AWG = 245'  18AWG = 490'    

Communication volume is too loud or too soft 

It's possible the volume control is not adjusted properly. Remove the front cover of the C-ML/A and locate the volume potentiometer through a hole located at the bottom of the station. Use a small screwdriver to adjust the volume; clockwise to increase, and counterclockwise to decrease. Do not turn the potentiometer too hard in either direction or damage may occur.    [post_title] => Common Communication Troubleshooting for the C-123 Kit [post_excerpt] => [post_status] => publish [comment_status] => open [ping_status] => open [post_password] => [post_name] => common-communication-troubleshooting-for-the-c-123-kit [to_ping] => [pinged] => [post_modified] => 2025-03-12 08:41:18 [post_modified_gmt] => 2025-03-12 15:41:18 [post_content_filtered] => [post_parent] => 0 [guid] => https://aiphone.local/kb/common-communication-troubleshooting-for-the-c-123-kit/ [menu_order] => 0 [post_type] => kb [post_mime_type] => [comment_count] => 0 [filter] => raw ) [comment_count] => 0 [current_comment] => -1 [found_posts] => 1 [max_num_pages] => 1 [max_num_comment_pages] => 0 [is_single] => [is_preview] => [is_page] => [is_archive] => 1 [is_date] => [is_year] => [is_month] => [is_day] => [is_time] => [is_author] => [is_category] => [is_tag] => [is_tax] => 1 [is_search] => [is_feed] => [is_comment_feed] => [is_trackback] => [is_home] => [is_privacy_policy] => [is_404] => [is_embed] => [is_paged] => [is_admin] => [is_attachment] => [is_singular] => [is_robots] => [is_favicon] => [is_posts_page] => [is_post_type_archive] => 1 [query_vars_hash:WP_Query:private] => cb8547f66fac6b25bb636d2ac8dfe062 [query_vars_changed:WP_Query:private] => 1 [thumbnails_cached] => [allow_query_attachment_by_filename:protected] => [stopwords:WP_Query:private] => [compat_fields:WP_Query:private] => Array ( [0] => query_vars_hash [1] => query_vars_changed ) [compat_methods:WP_Query:private] => Array ( [0] => init_query_flags [1] => parse_tax_query ) )

C-123 Speakers Squeal and Station Overheats

Summary 

Upon power up, the C-ML/A maser station squeals and the batteries seem to overheat. 

 

Cause 

Power supply and batteries are both installed. 

 

Solution 

Take batteries out of the C-ML/A master station if powered with an SKK-620C power supply. Both power sources cannot be used simultaneously. 

  